What the record shows about carbon monoxide in an occupied sleeper berth, and what no study has measured.
November 2026
Part one: The setup
A driver idles for heat and power, sleeps ten hours in a berth that can sit beside other idling trucks, and repeats it the next night for years.
Federal hours-of-service rules require 10 consecutive hours off duty before a driver starts a driving shift (49 Code of Federal Regulations [CFR] 395.3(a)(1)). A driver can take all 10 hours as sleeper berth time (49 CFR 395.1(g)(1)). The scenario later in this brief uses that 10-hour night.
Idling supplies heat and air conditioning, and it powers appliances such as a microwave or television. The 2010 Federal Motor Carrier Safety Administration (FMCSA) brief said the simplest fix for in-cab air quality would be to prohibit idling while a driver rests in the berth, and that doing so would severely limit those comforts (Fu et al. 2010).
The phenomenon has a name in the vehicle engineering literature: self-pollution. It means a vehicle’s own exhaust finding its way into its cabin. The United Nations Economic Commission for Europe’s Vehicle Interior Air Quality group (VIAQ) uses the term for exactly this: exhaust gas from the vehicle’s own tailpipe entering the cabin (source 35).
Self-pollution has been measured. In three gasoline passenger cars tested idling and moving in Lebanon, the cars’ own exhaust supplied an average of about 15% of in-cabin carbon monoxide and 30% of in-cabin fine particles (Harik et al. 2017, source 67). Those were cars, and no diesel truck or sleeper berth was tested (Scoped).
Every finding below carries one of four labels.
- Confirmed. Checked against the primary document.
- Scoped. The result is real but was measured somewhere else, such as a passenger car or a garage.
- Searched, none located. A search of the sources in the source list found nothing. That doesn’t prove the data don’t exist.
- Unresolved. The claim needs a document that hasn’t been read.
Bottom line: the exposure is an idling engine, a sleeping driver and a night repeated for years.
Sources: 3, 5, 67. Labels: Confirmed; Scoped (Harik, passenger cars).
Part two: What carbon monoxide does in blood
Carbon monoxide (CO) binds to hemoglobin, the oxygen-carrying protein in red blood cells, and forms carboxyhemoglobin (COHb). COHb is reported as a percentage of total hemoglobin. The Haldane coefficient (M) is the ratio of hemoglobin’s affinity for CO to its affinity for oxygen. The Agency for Toxic Substances and Disease Registry (ATSDR) lists M as 218 in its Coburn-Forster-Kane table, with a stated range of 191 to 257. Equilibrium binding constants give about 234. CO binds roughly 200 to 250 times more tightly than oxygen.
COHb falls after exposure ends with a half-life of about 5 hours in a resting person breathing room air. Peterson and Stewart (1970) reported a mean of 320 minutes, range 128 to 409, for peak COHb of 2 to 15%. Bruce and Bruce (2006) reported 248 minutes, range 206 to 328, at 15 to 20%. This brief uses 320 minutes because the berth-range values below sit inside the 2 to 15% group.
Muscle keeps taking up CO for about 300 minutes after exposure ends, then returns it to the blood (Bruce and Bruce 2006, as summarized by ATSDR). A swine study at 940 ppm found COHb decay fit two compartments and COHb rebounded after oxygen stopped, consistent with CO stored outside the blood (Delvau et al. 2024). That is a high-dose animal model (Scoped).
On 100% oxygen at normal pressure, the half-life drops to a mean of 74 minutes (standard deviation 25) (Weaver et al. 2000). That is a treatment figure for poisoned patients and does not describe a berth figure (Scoped).
Bottom line: COHb rises toward an equilibrium set by the air and falls with a half-life of roughly 3 to 5 hours, depending on the source.
Sources: 1, 2, 14, 18. Labels: Confirmed (ATSDR values); Scoped (Weaver, Delvau).
Part three: What the berth rules say, and what they leave out
| Provision | What it covers |
|---|---|
| 49 CFR 393.76(f) and (g) | (f) addresses ventilation of the sleeper berth. (g) addresses exhaust and fuel leaks into it. |
| 49 CFR 393.77(a)(6) | Portable heaters are prohibited in any space occupied by persons, except a cargo space being loaded or unloaded. |
| 49 CFR 393.83(e) and (g) | Exhaust must discharge to the rear of the cab. No leak forward of or directly below the driver and sleeper compartment. Part 396, Appendix A, section 3(a) carries the inspection version. |
| 49 CFR 393.77(b)(9) | The only CO number in Part 393: 0.2% (2,000 ppm), in a design proviso for cargo-space heaters. It governs heater design in cargo spaces and sets no occupant limit. It is 57 times the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit (REL) of 35 ppm. |
| 49 CFR 392.66 | Bars dispatching or driving a commercial motor vehicle, or permitting passengers on it, when an occupant has been affected by CO or CO has been detected in the interior. It also covers a discovered mechanical condition likely to produce a CO hazard. The trigger is knowledge of CO, whatever the engine is doing. The text says “dispatch or drive” and doesn’t mention a parked vehicle. |
| 49 CFR 395.1(g)(1) | Sleeper berth time counts toward the 10 consecutive hours off duty. |
The provisions above regulate how the vehicle is built and inspected. Part 393 contains no requirement for a CO detector or alarm in a commercial sleeper berth, and no limit on CO in the occupied berth while in service (Searched, none located). Paragraph (a)(2) turns on CO having been detected, and Part 393 requires no detector, so the rule has nothing to act on unless someone is already measuring. Whether 392.66 reaches a parked, sleeping driver is Unresolved. The Washington FACE report lists 392.66 under its employer requirements but states no reading on parked vehicles and rests on preliminary data (Source 19). The National Fire Protection Association (NFPA) standard for recreational vehicles (RVs), NFPA 1192 (2026 edition), Section 6.1.2, requires every RV to carry a CO alarm listed under UL 2034 or CSA 6.19. This brief located no equivalent requirement for a commercial sleeper berth. NFPA 1192 defines an RV as a vehicle or slide-in camper primarily designed as temporary living quarters for recreational, camping, or seasonal use (Section 3.3.53), and a commercial sleeper berth does not appear to fall within that definition.
Outside the United States, a heavy truck’s sleeping place does get a CO limit at certification. Russia’s interstate standard GOST 33554-2015, developed by the Russian automotive institute NAMI and adopted in 2015 by six member states of the Euro-Asian Council for Standardization, Metrology and Certification, caps CO in the occupied compartment of M and N category vehicles at 5.0 mg/mÂł, about 4.4 ppm at 25 degrees Celsius. That value is Russia’s maximum one-time limit for outdoor air in populated areas. For N2 and N3 trucks with a sleeping place, the standard adds a sample point at the sleeper’s head, 0.3 to 0.4 meters above the bunk on the exhaust side, during a 20 to 30 minute idle test run with the forced ventilation on and again with it off. A reading above the limit at any point fails the vehicle, and the standard’s report form ties the result to the Customs Union vehicle safety regulation, TR TS 018/2011. It took effect in Russia on April 1, 2017. The test runs with the driver and test operator aboard and nobody asleep, and it lasts minutes. GOST 33554-2024 replaced it on July 1, 2025; the 2024 text was not located free of charge, so whether its CO limit changed is Unresolved (source 70).
Occupational Safety and Health Administration (OSHA) coverage is a separate open question. Section 4(b)(1) of the Occupational Safety and Health Act (29 U.S. Code 653(b)(1)) bars OSHA from regulating working conditions where another federal agency has exercised its authority over them. Under Chao v. Mallard Bay Drilling, 534 U.S. 235 (2002), the test turns on whether that agency has exercised the authority. Whether FMCSA’s berth rules displace OSHA for a parked, sleeping driver is Unresolved. OSHA’s own 1989 policy review of section 4(b)(1) says OSHA is preempted only for working conditions that the Department of Transportation motor carrier rules address, keeps authority where DOT has not acted, and treats a negative exercise of authority as able to oust OSHA. It does not address a parked, sleeping driver, and OSHA’s trucking page says OSHA keeps authority over intrastate trucks. No OSHA interpretation letter on a sleeping driver was located.
No federal idling law exists. A fifty-state read of the rule texts found 20 states with no idling limit located, 17 states plus the District of Columbia with a general statewide limit, 2 states (Hawaii and Virginia) with statewide rules of narrow scope, and 11 states with local or regional limits only. Hawaii’s rule covers off-street areas such as loading zones and route terminals. Virginia’s covers commercial and public-service vehicles in commercial or residential urban areas. Most statewide limits carve out an occupied sleeper berth in some form, and the conditions vary: temperature bands in Oregon and South Carolina, designated locations or 1,000 feet from housing in Colorado, no truck-stop electrification within 25 miles in Delaware, and engine model year in New Jersey and Vermont. Pennsylvania’s sleeper exemption expired May 1, 2010. The exception lists in New York, New Hampshire, Hawaii and the District of Columbia have no sleeper berth entry. California removed its sleeper exemption on January 1, 2008 (13 California Code of Regulations 2485). Idaho went the other way in 2024 and now allows a commercial vehicle to idle for heating or air conditioning while the driver rests (House Bill 533). North Carolina repealed its heavy-duty idling rule effective November 1, 2016. None of the idling provisions read for this brief mentions CO.
Bottom line: the U.S. rules govern how the berth is built and inspected. None sets a limit on the air a sleeping driver breathes, and none requires a detector. Russia’s vehicle certification standard sets a CO limit at the sleeper’s head.
Sources: 3, 9, 20, 21, 22, 70. / Labels: Confirmed (rule text, state rules read; GOST 33554-2015 text read); Unresolved (GOST 33554-2024 limits); Searched, none located (states with no limit; detector requirement); Unresolved (OSHA jurisdiction; reach of 392.66 to a parked vehicle).
Part four: What has been measured
| Measurement | Setting | Result | Label |
|---|---|---|---|
| Fu et al. 2010 (FMCSA-RRR-10-010, 27 trucks) The final report puts parked-idling averages at about 1.5 times the on-road averages for CO, 7.1 times for oxides of nitrogen and 3.0 times for fine particles (Executive Summary; section 5.3.2). The Tech Brief gives 1.3, 4.8 and 4.5 for the same parked-against-on-road comparison, so this brief uses the final report. | Instruments in the berth trough with the bottom mattress removed, overnight rest area at a truck stop, parked idling, 1-hour averages by engine and air-conditioning mode. The journal abstract gives the trucks as model years 2006 to 2008 from four manufacturers. | CO in every mode well below the 50 ppm OSHA 8-hour limit. Average 1-hour in-cab CO (Table 7): 0.40 ppm with engine and HVAC off (0.30 ppm outside), 0.47 ppm with engine on and fresh air, 0.51 ppm with engine on and fan off, 0.59 ppm with engine on and recirculation. The report says the person or people in the cab adjusted its temperature during air-conditioning runs, and it describes no sleeping occupant. It gives the maximum average CO as about 3.5 ppm, on engine-on recirculation (section 4.5.3). No test truck had a closed crankcase ventilation system; blow-by gases vented to the atmosphere (section 3). | Confirmed (design; Table 7 values; sections 3, 4.5.3 and 5.3 read); occupant present to set cab temperature, no sleeping occupant. |
| FMCSA “Study of Alternatives to Reduce Driver Exposure to Diesel Exhaust” (FY2015 funding $481,078; contractors University of Michigan Transportation Research Institute, Texas A&M Transportation Institute, Georgia Institute of Technology). | Follow-on to the 2010 in-cab measurements; evaluated idle-reduction technologies for trucks at rest stops. | The pollutant of concern was diesel particulate matter (PM2.5), not carbon monoxide. The background field work measured air pollution inside truck cabs and sleeper berths at truck stops and found it exceeded EPA air quality standards, worse when trucks were idling. | Confirmed (FMCSA project page); Scoped (particulates, not CO). |
| Doraiswamy et al., as reported in Fu et al. 2010. | Six sleeper trucks (model years 1996 to 2003) idling at a truck-stop rest area | Average 1-hour in-cab CO: 0.42 ppm with engine and air conditioning off; 0.49 to 0.82 ppm with the engine on, depending on the air setting. | Confirmed as reported; Scoped |
| Lee et al. 2009 (Transportation Research Record 2123:17-25) | One 2006 International tractor with a Cummins ISX 15-liter engine, parked and idling at a truck stop in Socorro, Texas (258 spaces, about 283 trucks parked overnight, about 60 idling). May 17 to 20, 2007, at 15 to 28 degrees Celsius. A CO analyzer inside the cab alternated with an ambient sample line every 10 minutes. Each air-conditioning mode ran 7.75 to 17 hours. The paper doesn’t say whether anyone was in the cab. | Mean in-cab CO against ambient: 0.29 against 0.17 ppm with outside air on; 0.94 against 0.15 ppm in recirculation (ratio 6.27); 1.16 against 0.20 ppm on the auxiliary power unit (ratio 5.80); 0.17 against 0.17 ppm on the plug-in electrified unit (ratio 1.00). The authors attribute the excess to engine emissions entering through openings in the cabin, possibly crankcase emissions through openings in the cabin floor. | Confirmed (Table 3 values); Scoped (one truck, one site, summer, no occupant stated) |
| Mabvuta 2015 (University of Alabama at Birmingham master’s thesis) | Two rental sleeper tractors, a 2011 model for 9 nights and a 2013 model for 12, both with diesel exhaust filters. Parked and idling at a truck stop in Birmingham, Alabama (157 spaces, full on all 21 nights), January 26 to February 19, 2015. Each run lasted about 10 hours, roughly 6:30 to 7:30 pm until 4:30 to 5:30 am, with windows closed. The investigator, a CDL holder, rested or slept in the bunk. Area sampling for diesel particulate (elemental and organic carbon) and PM2.5, inside and outside the cab. | CO was not measured. Elemental carbon (EC) geometric mean 4.87 µg/mÂł inside against 1.99 outside (p = 0.0014). Mean inside EC was 3.1 in the first truck and 9.5 in the second. PM2.5 geometric mean 31.2 µg/mÂł inside against 23.9 outside (Table 4), about 30% higher but not statistically significant (p = 0.337). Inside and outside EC were not significantly correlated (r = 0.39, p = 0.081); PM2.5 was (r = 0.6, p = 0.005). The author attributes the excess inside to the truck’s own exhaust. | Confirmed (Tables 4 and 5, Methods); Scoped (particulates, not CO; one investigator, one site, two trucks) |
| Virginia Tech Transportation Institute (VTTI) pilot study (data July to December 2023; report posted 2025) | Two Virginia Department of Transportation truck-mounted attenuator work trucks in work zones, 39 operating days each | Parked on the road, the trucks averaged 1.63 ppm (Truck 1) and 1.98 ppm (Truck 2). In parking facilities the report’s abstract says levels stayed consistently low and gives no figure. | Confirmed; Scoped (not berths) |
| UNECE VIAQ Mutual Resolution No. 3, second-stage amendment (exhaust-gas entry). | Harmonized test procedures for measuring exhaust-gas entry from a vehicle’s own tailpipe into its cabin. Test substances include CO, NO, and NO2. | The procedures exist. No limit values were set. The resolution states that setting interior emission limit values is not part of the recommendation, and it holds no regulatory status. Scope is passenger vehicles and vans. A Russian draft standard submitted to the VIAQ group covers M-category (passenger) and N-category (goods) vehicles, names exhaust gases penetrating through ventilation systems and body cracks as the contamination mechanism, and was used in Russian vehicle certification. The adopted standard is GOST 33554-2015 (source 70): the same developer, nearly the same title, the same vehicle categories and the same three CO measurement methods as the draft, though neither document names the other. A 2017 NAMI presentation to the VIAQ group (VIAQ-08-07) reports about 2,450 vehicles tested under the earlier Russian edition from 2009 to 2016, with 51 failing, 3 of those on CO, and 84% of failures at idle. | Confirmed (UNECE documents; GOST 33554-2015 text and NAMI presentation read); Scoped (UNECE resolution: not US, not sleeper berths, no limits, no overnight measurements; GOST: short certification test, no sleeping occupant). |
| Dirks et al. 2018 (Auckland) | Passenger car on the “new air” setting, stopped behind an old, poorly tuned truck at a traffic light | 171 ppm peak for 10 seconds. The abstract says 170; the body says 171. | Confirmed; Scoped (not a berth) |
| Ziskind et al. 1977 (Federal Highway Administration, NTIS PB275957) | Continuous CO, nitric oxide and nitrogen dioxide measurement plus a tracer-gas subprogram in 88 heavy-duty diesel tractors from eight large fleets (53 tested at idle, 50 on the road, many both). Average age 5.7 years, prescribed fleet maintenance, owner-operators excluded. A technician rode along on road tests. The report describes no sleeping occupant. | Highest total in-cab CO was 30 ppm, 85% of the 35 ppm proposed limit. Highest vehicle-added CO was 10.5 ppm on the road with windows slightly open. Highest at idle was 3.0 ppm. Closed windows and vents were the worst case for CO at idle (p of .05 or less). For CO, exhaust leaks and floor openings were suggestive but not statistically significant. Tracer gas on two cab-over tractors with windows and vents closed showed entry mainly through the gearshift and foot-pedal floor openings. A release at an exhaust leak put about ten times more gas in the cab than the same release from a high stack, and idle ran about ten times higher than road. The authors estimate vehicle-added CO adds at most 1.5% COHb and rank it the least important of the CO factors they weighed. They note COHb can take up to ten hours to reach equilibrium at low CO and call 8 to 10 hour exposure a needed area of study. | Confirmed (full report read); Scoped (1970s fleet tractors, two-tractor tracer test, no sleeping occupant) |
| Doraiswamy et al. 2005 (University of Tennessee report to EPA, full text read). The same group’s 2006 journal paper (Transportation Research Record 1987:82-91) was read at abstract level only. | Six sleeper trucks (model years 1996 to 2003) parked at a truck stop at Interstate 40 and Watt Road in Knox County, Tennessee (about 225 spaces), December 2004 and January 2005, day and night. One-hour bag samples analyzed for CO by infrared gas filter correlation (detection limit 0.04 ppm). In-cab inlet near the middle of the cab, about 2 feet above the sleeper bed; outside inlet in front of the windshield, above the fresh-air vents. Four modes: engine off, recirculation, fresh air, and engine on with the fan off. Cab temperature was set for the comfort of the person collecting data, and an observer sat in the cab for the first hour. The report describes no sleeping occupant. | In-cab CO stayed typically below 2 ppm in every mode; the highest 1-hour in-cab sample was 2.07 ppm (truck 3, recirculation). The authors report in-cab CO and nitrogen oxides consistently higher than outside in the recirculation and fresh-air modes and name the truck itself as a source. With the engine on and the fan off, in-cab PM2.5 rose for the full hour in all six trucks, to 2 to 31 times its starting level, which the authors read as engine emissions entering by routes other than the vents, possibly crankcase blow-by through floor openings. A repeat test in an empty lot with no other trucks behaved the same way. Estimated air exchange with the engine off was 1.0 to 2.2 changes per hour. The authors note that diesel trucks typically emit little CO because the engines run with high excess air, and they recommend sampling inside the engine compartment. | Confirmed (full report read; CO maximum from Appendix A-7); Scoped (six trucks, one site, winter, 1-hour samples, no sleeping occupant) |
| Davis et al. 2006 (WIT Transactions on Ecology and the Environment 86:565-574). One author was with IdleAire Technologies, the electrification vendor whose system was tested. | 16 trucks (model years 1995 to 2004) at a travel center at Interstates 40 and 75 and Watt Road near Knoxville, Tennessee (about 225 spaces), July and August 2004. Laser particle counter, 1-minute readings, sample point in the center of the sleeper about 30 inches above the floor. Idling with air conditioning on outside air or on recirculation, then engine off with truck stop electrification. The paper does not state whether anyone was in the cab. | The cab study measured particles only. With the engine idling on recirculation, four trucks read higher inside than outside with the truck running; the authors attribute it to inleakage around the engine cowl area and door seals. The text names trucks 3, 8, 9 and 16, while Table 1 shows the negative values for trucks 3, 8, 9 and 17 (a repeat test of truck 1). In truck 3, cab particles passed 350 µg/m³ in under 40 minutes and generally exceeded outside levels, and the authors judge an internal exhaust leak highly likely. Particles outside the driver’s window averaged 3.8 times higher with the test truck idling than with it off. Separate lot monitoring from December 2003 to August 2004, with about 60 to 130 trucks idling, found 1-hour ambient CO never above 1.9 ppm. | Confirmed (full paper read); Scoped (particles only in the cab, no occupant stated, vendor coauthor; text and Table 1 differ on truck numbers) |

Figure 1. Measured CO readings against exposure limits (log scale). The two Virginia Tech trucks are work trucks; the Auckland reading is a passenger car. Limit lines: World Health Organization (WHO) 8-hour and 15-minute guidelines, NIOSH REL, OSHA permissible exposure limit (PEL), and the 393.77(b)(9) cargo-heater design proviso. Sources: 3, 6, 7, 9.
Averages in the two VTTI trucks were 1.22 and 1.61 ppm, with peaks of 10.05 and 8.59 ppm. The report ties the peaks to prolonged idling and to acceleration near congested traffic, and it also lists open windows. Peaks ran about 8 times the mean in the first truck and about 5 times in the second.
The WHO 2021 global air quality guidelines for CO are 4 milligrams per cubic meter (mg/mÂł) over 24 hours, 10 over 8 hours, 35 over 1 hour and 100 over 15 minutes. At 25 degrees Celsius those are about 3.5, 8.7, 31 and 87 ppm. The 2010 WHO indoor guideline is 7 mg/mÂł over 24 hours, about 6.1 ppm.
The 2010 FMCSA report also measured fine particulate matter of 2.5 micrometers or smaller (PM2.5). The Tech Brief reports high PM2.5 with the engine on and the heating, ventilation and air conditioning (HVAC) system on fresh air, and with the engine on and the fan off, and says it exceeded the National Ambient Air Quality Standards (NAAQS) then in force: 35 micrograms per cubic meter (µg/m³) over 24 hours and 15 µg/m³ annually. The final report is more cautious, describing PM2.5 as around the NAAQS limits, and its Table 7 values depend on the instrument: 51 and 48 µg/m³ by optical particle counter with the engine on (fresh air and fan off), against 22 and 19 µg/m³ by DataRAM (section 5.3.1; Table 7). With the engine and HVAC off, PM2.5 stayed relatively low. The NAAQS apply to community monitors and are averaged over three years, so the comparison is a benchmark and does not show a violation. The 24-hour standard is unchanged. The U.S. Environmental Protection Agency (EPA) lowered the annual standard to 9.0 µg/m³ in 2024, and it remains in effect as of October 2026.
Two other parked-truck studies measured in-cab PM2.5. Lee et al. (2009) measured 7.02 inside against 16.1 µg/m³ outside on plug-in power, with the air conditioner filtering it. Mabvuta (2015) measured a geometric mean of 31.2 inside against 23.9 outside (Table 4), about 30% higher but not statistically significant, and elemental carbon ran higher inside as well.
Truck age may matter. Davis et al. (2007) sampled in-cab particles in diesel trucks from 36 terminals and found that elemental carbon rose with truck age (R2 = 0.34, p < 0.01). The authors suggest that exhaust seeps into older cabs through worn rubber seals. That analysis covered particles, not CO, and it was not done in a sleeper berth. No study located ties truck age to CO in an occupied berth.
Three of the studies above share University of Tennessee authors and Knoxville-area truck stops: Fu et al. 2010, Doraiswamy et al. 2005 and Davis et al. 2006. They are related work and should not be counted as independent confirmations. Davis et al. 2006 and Davis et al. 2007 are different research groups.
Bottom line: no CO reading located in the record comes from an occupied berth over a full night. Where study means are reported, in-cab CO ran from about 0.2 to 2.0 ppm. The highest average reported for a single parked truck is about 3.5 ppm (Fu et al. 2010), and the highest peak is 10.05 ppm in a work truck. The one overnight occupied-bunk study measured particulates, not CO.
Sources: 5, 6, 7, 9, 27, 28, 29, 31, 60, 61, 64, 65, 70. Labels as shown in the table. Searched, none located (CO in an occupied berth over a full night).
Part five: A two-night scenario
This is a model scenario, not a measurement. It shows what a single-compartment model predicts for a nonsmoking driver at rest, sleeping 10 hours in a berth at a steady CO level, then spending 14 hours awake with no CO exposure.
Model inputs. Half-life 5.1 hours, within 5% of the 320-minute mean from Peterson and Stewart. Baseline COHb 0.78%. An equilibrium rise of 0.156 percentage points of COHb per ppm. The baseline and the rise per ppm are scenario inputs, not measured values.
One caveat cuts the other way. The National Research Council’s 2007 review of submarine air notes that CO’s elimination half-life lengthens to about 8 hours during sleep. This model uses 5.1 hours. If that figure holds for a sleeping driver, less CO clears overnight than the model shows (Scoped; the NRC’s underlying primary source was not read).
| Berth CO | End of night 1 | 14 hours later | End of night 2 | Repeating cycle |
|---|---|---|---|---|
| 10 ppm | 1.9% | 1.0% | 2.0% | 2.0% |
| 25 ppm | 3.7% | 1.2% | 3.8% | 3.8% |
| 35 ppm | 4.8% | 1.4% | 5.0% | 5.0% |

Figure 2. Scenario COHb over two nights at three berth CO levels. Nonsmoker at rest. The 2.0% line is the COHb basis of the WHO indoor guidelines. Model outputs are calculations from stated inputs; they are not measurements. Sources: 1, 2, 9.
Ten hours reaches about three quarters of the way to equilibrium. At 25 ppm, equilibrium is about 4.7% COHb and the 10-hour endpoint is 3.7%. About 15% of the rise is still present after 14 hours awake, so night two starts above night one: 1.2% against 0.8% at 25 ppm. The cycle settles after about three nights.
The levels need context. 10 ppm is the highest peak reading in the VTTI trucks, whose means were 1.2 to 1.6 ppm. 25 and 35 ppm are hypothetical levels chosen to bracket the NIOSH REL of 35 ppm; no berth measurement supports them. Measured in-cab means in the studies above run about 0.2 to 2.0 ppm, so the 25 and 35 ppm rows sit roughly 13 to 18 times above the highest measured mean, and the 10 ppm row about 5 times above it. Run through the same model, a steady 2.0 ppm gives about 1.0% COHb by morning, within 0.25 points of the 0.78% baseline. The scenario therefore describes a sustained level, and the measured averages sit near the baseline. Whether peaks or long stretches near the higher rows occur in an occupied berth is the unmeasured part. The scenario inputs also run higher than the International Labour Organization (ILO) Encyclopaedia, which gives about 5% COHb at equilibrium for 35 ppm and a COHb half-life of 3 to 4 hours in sedentary adults; the fitted scenario reaches about 6% at equilibrium with a half-life near 5 hours. Published values differ by source. The scenario also excludes smokers. NIOSH reported that 51% of long-haul drivers smoke, against 19% of working adults, and smokers typically carry a baseline COHb of 5 to 10% before any berth exposure (NIOSH 2010).
Bottom line: under the scenario inputs, a nonsmoker at rest reaches about 1.9 to 4.8% COHb by the end of the first night at 10 to 35 ppm, settling at 2.0 to 5.0% after a few nights. The 25 and 35 ppm levels are hypothetical, and measured in-cab means of about 0.2 to 2.0 ppm would sit near the baseline.
Sources: 1, 2, 6, 9, 10, 27. Label: Scoped (scenario).
Part six: What the health literature supports
Every study in this section either measured acute poisoning, an occupational group, or a laboratory exposure. None measured a sleeping driver.
Heart. EPA (2000) reported cardiac effects in people with coronary artery disease at 2.4 to 6% COHb. Allred et al. (1989) exposed 63 men with coronary artery disease to CO that raised COHb to 2.0% and 3.9%. Exercise time to angina onset shortened by 4.2% and 7.1%, and time to ST-segment change on the electrocardiogram shortened by 5.1% and 12.1%. Kleinman et al. (1989) studied 24 men with COHb raised from about 1.5% to 3% and reported time to angina down about 6%. Both are abstract-level readings (Scoped).
Occupational cohorts. In New Jersey motor vehicle examiners, 124 cardiovascular deaths were observed against 118.4 expected (Stern et al. 1981). In New York City, 5,529 bridge and tunnel officers were followed from 1952 to 1981. Former tunnel officers had 61 arteriosclerotic heart disease deaths against 45 expected (standardized mortality ratio [SMR] 1.35, 90% confidence interval 1.09 to 1.68). Risk did not track length of exposure, and the excess declined after exposure ended, with much of it gone within as little as 5 years. Average COHb was under 5%, and the exposure was intermittent shift work (Stern et al. 1988) (Scoped).
Mechanic garages. In a prospective cohort of 99 auto service workers in Kayseri, Turkey, COHb ranged from 0 to 18% against 0 to 4% in controls. At any measurement, 10 smokers (18% of smokers) exceeded 10% COHb and 33 nonsmokers (73% of nonsmokers) exceeded 5%. The thresholds differ by smoking status, and “at any measurement” means one high reading across four, and it does not show persistent elevation (Bol et al. 2018) (Scoped).
Behavior. EPA (2000) reported no statistically detectable behavioral impairment until COHb exceeds 20 to 30%. The scenario peaks above sit far below that range.
Federal literature review (2007). A literature review prepared for FMCSA by the Volpe Center looked for cognitive effects of diesel exhaust and found that, among exhaust components, only carbon monoxide had been studied, mostly in controlled laboratory settings at 0 to 200 ppm and COHb from under 1% to 10% and higher (Yeh and Pollard 2007). It reports that Wright and colleagues (1973) found a 3.4% rise in COHb, from 100 ppm for 2 hours, could impair driving judgments, and that McFarland (1973) found COHb above 11% produced some tunnel vision. It also reports that O’Donnell and colleagues (1971) found no negative effect of CO exposure on sleep, with more deep sleep in exposed participants and no effect on cognitive functioning. EPA’s 1991 criteria document (Source 71) gives the exposure: sleepers at 75 and 150 ppm, reaching COHb up to 12.7%, with small, unreliable changes in sleep. The primary paper was not read (Scoped). These are secondhand summaries of 1970s laboratory studies, and the review says it is not clear whether the CO levels drivers meet match the levels tested (Scoped, secondhand).
Repeated exposure. The ILO Encyclopaedia says CO does not accumulate in the body and is completely excreted after each exposure if enough time in fresh air is allowed. It adds that repeated mild or moderate poisonings that do not cause unconsciousness could kill brain cells and lead to central nervous system damage, and it frames that as possible, not demonstrated. The entry also names road transport drivers as at risk if engine exhaust leaks into the cab (ILO) (Scoped).
Noise plus CO and hearing. In 9,396 audiograms collected in Quebec from 1983 to 1996, workers classed as exposed to both noise and CO had poorer thresholds at 3, 4 and 6 kHz than workers with no or negligible CO exposure (p < 0.001) (Lacerda et al. 2005). A fuller analysis of the same database found the interaction at noise doses of 90 dB(A) over 8 hours or more, and no significant effect with noise below 90 (Leroux et al. 2008). FMCSA measured in-cab noise well below 90 dBA during on-road driving in 22 of the 27 road-tested trucks (Fu et al. 2010, p. 23). That study measured noise on the road, not in a parked, idling berth, so this finding does not transfer to truck cabs on current evidence. Measured CO levels were not stated in the sources read (Scoped).
Chronic low-level cohort. One single-author occupational cohort in Mashhad, Iran followed workers for more than 10 years across five working sections, with CO measured by a data logger. Mean CO ran from 6.10 to 9.01 ppm across the sections and was highest in section B. In section B, Table 3 reports relative risks of 1.60 (95% confidence interval 1.09 to 2.33) for palpitation, 1.62 (1.07 to 2.43) for chronic fatigue, 1.60 (1.08 to 2.13) for memory and 1.58 (1.10 to 2.13) for decision-making. Relative risks are reported between working sections, and the study has no unexposed group. The paper does not address smoking, and the percentages in its Table 2 do not match its stated group size of 200. The abstract’s last two relative risks (1.50 and 1.46) are section E values for memory and decision-making (Assadi 2019). Labels: Confirmed (Table 3); Scoped (occupational setting, not a berth).
Duration. EPA (2000) found that for vascular effects, duration of exposure matters more than inspired concentration alone predicts, and said duration effects had not been adequately investigated. That is the central gap.
Smoking adjustment. A 2025 PLOS ONE scoping review of 80 papers found a COHb diagnostic range of 2% to 15% across studies and found that only 32.5% adjusted for smoking (Moss et al. 2025).
Delayed effects after acute poisoning. All rates below come from acute poisoning, not low-level exposure.
| Source | Population | Result | Label |
|---|---|---|---|
| Choi 1983 | 2,360 acute CO poisoning patients | Delayed neurological sequelae in 2.75% of all patients and 11.8% of admitted patients. Lucid interval 2 to 40 days (mean 22.4). Of 36 followed, 75% recovered within 1 year. | Confirmed (abstract) |
| Weaver et al. 2002 | 152 symptomatic hospital patients, 76 per arm | Cognitive sequelae at 6 weeks: 46.1% after normal-pressure oxygen against 25.0% after hyperbaric oxygen. | Confirmed (abstract) |
| Ho et al. 2026 | 2,421 hospitalized poisoning patients against 9,684 age- and sex-matched people from the general population, Taiwan, 2000 to 2015 | Deaths: 212 (8.8%) against 363 (3.7%). Of the 212: 76 suicides, 15 cardiovascular, 121 other. Adjusted hazard ratio for death 7.40. Psychiatric history in 16.0% of poisoned patients against 3.1%. Cardiovascular deaths were few (15 against 30). | Confirmed; Scoped (acute hospital poisoning, many intentional) |
Bottom line: the evidence comes from poisoning wards, occupational groups and short laboratory exposures. None measured a sleeping driver.
Sources: 5, 8, 11, 12, 13, 14, 16, 17, 23, 24, 25, 30. Labels as shown.
Part seven: Cases
The setting column gives the place of each case. Entries listed as sleeper berth are sleeper berth cases in the record, and the others are comparable exposures.
| Case | Setting | Note |
|---|---|---|
| Washington State Fatality Assessment and Control Evaluation (FACE) report 71-254-2024 | Sleeper berth, motor carrier terminal yard, January 19, 2023 | A 61-year-old driver died after sleeping overnight in the sleeper berth at his employer’s terminal yard (report dated June 1, 2024). Investigators found he was most likely poisoned by CO from a single-burner butane cooking stove found in the truck. Air monitoring in the sleeper and near the bunk heater’s exhaust while it ran showed no significant CO, and no exhaust leaks were found in the engine or undercarriage. The report says it rests on preliminary data and is not a final determination. It recommends battery-powered CO detectors in cabs and sleepers and a policy against fuel-burning stoves and heaters in them. 49 CFR 393.77(a)(6) bars portable heaters in occupied spaces. The report calls the device a cooking stove, and whether a butane stove counts as a portable heater is Unresolved. The report also cites 49 CFR 392.66 under its requirements and does not say whether the rule reaches a parked vehicle. |
| OSHA inspection 143281.015 | Sleeper berth, truck stop lot (Love’s), January 28, 2022 | Fatality summary from OSHA’s Integrated Management Information System (IMIS). |
| OSHA inspection 14529671 | School bus, February 7, 1989 | Fatality summary from IMIS. |
| Griffin et al. 2008 | Driver found in the secure cab of a running diesel tractor-trailer | First certified as ischemic heart disease, then re-certified as CO after toxicology. A 10-year review of 94 nonfire CO deaths at the Louisville, Kentucky medical examiner (1994 to 2003) and a literature review found no earlier reported diesel-exhaust CO fatality. The abstract lists ischemic heart disease as a contributing finding and notes the blood sample was putrefied, which limits the COHb reading. Cab, not a confirmed berth. Abstract only. The full text is behind a paywall and is not publicly available. |
| OSHA inspection 200626349 | Kiln building | CO “possibly” the cause. Comparable setting, not a berth. |
| OSHA inspection 14388052 | Crane | COHb 72%. Comparable exposure, not a berth. |
| Demirci et al. 2009 (case 1) | Parked truck cab | A 43-year-old driver died of CO poisoning while asleep in a parked truck, from a broken supplementary heater. |
| Demirci et al. 2009 (case 2) | Parked truck cab | A 48-year-old driver died in a fire caused by a supplementary heater set very high. Not a CO case. |
Bottom line: fatal cases exist in and around sleeper cabs. Their frequency is unknown.
Sources: 19, 15, 59. Labels: Confirmed (record entries); Scoped (comparables); Confirmed (abstract read only, because the full texts of Griffin and Demirci are paywalled and not publicly available).
Part eight: Patterns across the record
The rules govern the build. Every U.S. berth provision addresses where exhaust goes, how the cab is ventilated, and what the inspector checks. None sets a limit on the air a sleeping driver breathes, and none requires a detector to tell the driver when the air is bad. Russia’s certification standard does set a CO limit at the sleeper’s head (Part three).
The evidence is acute. Sequelae rates, half-lives and cardiac thresholds come from poisoning wards and short laboratory exposures. Chronic low-level exposure is extrapolated, and EPA said so in 2000.
Averages are low and peaks are not. In the two VTTI trucks, means of 1.2 to 1.6 ppm and peaks of 8.6 to 10.1 ppm. Model parameters are wide too: M ranges from 191 to 257 and half-life from 248 to 320 minutes depending on the source and the COHb range studied.
Detection and smoking confound the picture. Griffin’s case was first certified as a heart death, and the NTSB noted that toxicology for CO happens only in fatal accidents when a suitable blood sample exists. With 51% of long-haul drivers smoking and few studies adjusting for it, separating berth exposure from baseline is hard.
The fatality reports and the in-cab studies point to the same causes: leaks, heaters, stoves, and nearby idling. None measured the air around a sleeping driver, which supports the gap stated in Part nine. (Scoped)
Bottom line: the U.S. rules cover the build and the evidence covers acute poisoning. The exposure itself is unmeasured.
Sources: 3, 4, 6, 8, 10, 15, 17, 59, 60, 61. Observations drawn from the sections above.
Part nine: Gaps
| Gap | Label | What would close it |
|---|---|---|
| CO in an occupied berth over a full night | Searched, none located. The 2010 FMCSA final report (Table 7: 0.40 to 0.59 ppm, 1-hour averages, berth mattress removed) measured in-cab CO with the person or people in the cab adjusting the temperature and no sleeping occupant, and Lee et al. 2009 (7.75 to 17 hours per mode) measured it with no occupant stated. Mabvuta 2015 had an investigator in the bunk for 10 hours but measured particulates, not CO. Ziskind et al. 1977 sampled cab air at several interior points, including the head of the sleeper, with technicians aboard at idle, and reported no sleeper-specific results and no sleeping occupant (Source 60). Nearest data: Cheng (2006, University of Calgary dissertation) and Tan and Tay (2008) logged cab CO continuously over 24-hour periods including overnight idling in winter, at low single-digit ppm during idling with a brief spike near 6 ppm. The published summer methods place the sensor beside the front passenger seat, not in the sleeper berth, and driver location during the overnight idling was not recorded, so this does not establish CO in an occupied berth. Personal correspondence with CDC’s Hazard Evaluations and Technical Assistance Branch (October 2026) agreed the research on driver CO exposure in sleeper berths is limited and named no study that measured CO around a sleeping driver (62). | Measure CO in the berth of a sleeping driver for a full night, parked beside idling trucks in winter, and log peaks and duration as well as averages. The 2010 final report was checked on this point: section 3 says the person or people in the cab adjusted its temperature during air-conditioning runs, and section 4.5.3 reports 1-hour averages without stating total run time per mode. Two more near-misses belong on this list. FMCSA’s follow-on diesel-exhaust study (FY2015, $481,078) measured particulates in cabs and berths at truck stops, not CO. The UNECE VIAQ framework wrote test procedures for exhaust-gas entry into cabins including CO, but set no limit values and never applied them to a sleeper berth. The VTTI work-zone truck study (source 6) put CO sensors in real truck cabs and logged 1.22 to 1.61 ppm averages with peaks near 10 ppm, but those were work trucks, not berths, not overnight, not occupied berths. The NIOSH Health Hazard Evaluation program offers a free evaluation of a workplace hazard. A request must come from the employer or an authorized union representative. Three current employees may also request one. https://www.cdc.gov/niosh/hhe/request/index.html (63)Design notes from the record. Log carbon dioxide (CO2) beside CO through the night to estimate how fast the berth air turns over; with the engine off, Doraiswamy et al. estimated 1.0 to 2.2 air changes per hour (source 64), and the 2010 FMCSA final report measured about 130 minutes per exchange with the engine and air conditioning off in three trucks (Table 6, source 5). Place one CO sensor at the sleeper’s face and one mid-berth. In a sleeping-space airflow model checked against a heated manikin, exhaled CO2 pooled near the face: holding the breathing zone under 1,000 ppm took about 25 liters per second of supply air, against 7.2 liters per second for the whole space under a well-mixed assumption (Zhang et al. 2015, source 69; a generic transport sleeping space, not a truck). Sample inside the engine compartment to find leak sources, as Doraiswamy et al. recommended. Russia’s GOST 33554-2015 already places a CO sample point at a sleeping driver’s head, 0.3 to 0.4 meters above the bunk on the exhaust side (source 70); a full-night study can use the same point so its readings line up with that certification test. |
| Exposure from adjacent idling trucks | Searched, none located. Auckland is a car in traffic. Lee et al. 2009 recorded ambient CO of 0.13 to 0.20 ppm beside the test truck with about 60 trucks idling in the lot. Mabvuta found no significant inside-to-outside correlation for elemental carbon (r = 0.39, p = 0.081, 21 nights), which is weak evidence in either direction. The Washington FACE report (71-254-2024) recommends against idling or parking near idling trucks or auxiliary power units, because fumes can enter a truck with windows and vents closed. That is a state agency recommendation, not a measurement. The CDC reply to this brief’s author lists nearby idling trucks among the causes of higher cab CO and names no measurement of it (Source 62). Ziskind et al. 1977 isolated each truck’s own exhaust and tested no neighboring engines (Source 60). Davis et al. 2006 monitored lot air at a Knoxville-area travel center for nine months with about 60 to 130 trucks idling, and 1-hour ambient CO never exceeded 1.9 ppm, measured 4 meters above ground, not in a cab (Source 65). Doraiswamy et al. retested one truck in an empty lot and saw the same pattern as at the truck stop, which the authors take to mean the truck itself plays a major role in its own in-cab contamination (Source 64). | Paired in-cab and outside CO readings with and without neighboring engines idling. A tracer gas metered into the test truck’s exhaust would separate its own contribution from its neighbors’. In six school buses, sulfur hexafluoride (SF6) fed into the tailpipe showed that up to 0.3% of cabin air came from the bus’s own exhaust, and with a bus stopped and the wind from the rear, its exhaust reached a sample line outside at the front of the bus (Behrentz et al. 2004, source 68). |
| Aldehydes in an occupied berth | Searched, none located for an occupied berth. Lee et al. 2009 reports in-cab formaldehyde 21 times ambient with the truck idling and 32 times with the auxiliary power unit. The Tech Brief recommends research on whether formaldehyde and acetaldehyde are present. The Lee authors name exhaust ingress and insulation off-gassing as possible sources. | Full-night aldehyde sampling in an occupied berth, with a way to separate exhaust from off-gassing. |
| Dose-response for chronic low-level exposure in at-risk groups | Confirmed missing (EPA 2000). FMCSA’s 2007 review reached the same conclusion for cognitive effects. | Epidemiology in long-haul drivers with smoking adjustment. |
| Reversibility after years of exposure | Searched, none located. Nearest data: Stern 1988 | A driver cohort followed after exposure ends. |
| CO detector or alarm requirement | Searched, none located | A rulemaking record or FMCSA response on detectors. |
| FMCSA and OSHA authority over a parked, sleeping driver | Unresolved. 49 CFR 392.66 is worded as “dispatch or drive,” and no OSHA interpretation on a parked, sleeping driver was located. | An agency interpretation or court ruling. |
| Delayed effects of low-level exposure | Searched, none located. All figures are from acute poisoning | Follow-up of low-level cohorts. |
| EPA’s current CO position | Confirmed (primary source). The 2010 Integrated Science Assessment (EPA/600/R-09/019F) was read for this brief. It classes the evidence for long-term cardiovascular effects as inadequate to conclude that a causal relationship exists (Table 2-1, page 2-5; section 5.2.2, page 5-40). It classes central nervous system effects after short-term and long-term exposure as suggestive of a causal relationship (section 5.3, page 5-49). It assesses ambient CO and does not evaluate occupied vehicle cabs or berths. | Nothing open. A newer assessment would supersede it. |
EPA last issued a CO criteria document in June 2000 and last assessed the science in January 2010. EPA retained the CO standards on August 31, 2011. No new CO review was open as of October 8, 2026.
Bottom line: the open item that matters most is CO in an occupied berth over a full night.
Sources: 5, 8, 12, 19, 27, 28, 30, 62, 63, 64, 65, 68, 69, 70. Labels as shown.
Part ten: The file as it stands
One federal test came close. In December 2010 FMCSA published a University of Tennessee study of 27 trucks. Instruments sat in the sleeper berth trough, with the bottom mattress removed, during parked idling at a truck-stop rest area. CO stayed well below the OSHA 8-hour limit of 50 parts per million (ppm). The study reports 1-hour averages by engine and air-conditioning mode. Table 7 gives in-cab CO of 0.40 ppm with the engine and heating, ventilation and air conditioning (HVAC) system off, and 0.47 to 0.59 ppm with the engine on, highest on recirculation. The report says the person or people in the cab adjusted its temperature during air-conditioning runs, and it describes no sleeping driver and no full-night run. It gives the maximum average CO as about 3.5 ppm, on engine-on recirculation.
Two other studies came close in different ways. Lee et al. (2009) logged in-cab CO for 7.75 to 17 hours per air-conditioning mode in a truck at a truck stop, with means of 0.94 ppm on recirculation and 1.16 ppm on an auxiliary power unit, and no occupant stated. Mabvuta (2015) put an investigator in the bunk for 10 hours a night over 21 winter nights and measured particulates, not CO. The one measured fix in the record is engine-off power: with a plug-in electrified unit, in-cab CO matched ambient at 0.17 ppm in one truck at one site (Lee et al. 2009), and the 2010 Tech Brief suggests external electric power for the same reason. In a chamber test with 32 volunteers, 14 of them bus drivers, cabin air filters did not lower CO. The volunteers breathed diluted diesel exhaust for an hour at 1.1 ppm CO, and four automotive cabin filters, two of them with activated charcoal, left CO at 1.1 to 1.2 ppm. The charcoal filters cut nitrogen dioxide and hydrocarbons and reduced irritation symptoms (Rudell et al. 1999) (Scoped).
The longer question is what the same exposure does over years. EPA wrote in 2000 that reliable dose-response information for chronic low-level CO exposure in at-risk groups “currently is missing from the published literature.” The 2010 EPA assessment still classed the evidence for long-term cardiovascular effects as inadequate to conclude that a causal relationship exists. FMCSA’s own 2007 literature review, prepared by the Volpe Center, said the agency was concerned that long in-cab exposure could affect drivers’ sleep, alertness or judgment, and found that very little is known about the cognitive impact of diesel exhaust exposure (Yeh and Pollard 2007).
For people who sleep in a low-level CO environment for years, whether any effect reverses is unknown. The closest evidence is occupational: among former New York City tunnel officers, excess heart disease mortality declined after exposure ended (Stern et al. 1988). No follow-up of long-haul drivers after years of berth exposure was located.
The closest federal work on berth sleep did not look at air. FMCSA’s 2002 sleeper berth study (Dingus et al., 56 drivers from 4 for-hire carriers) monitored sleep in the berth and recorded noise, vibration and temperature. It found berth sleep shorter and poorer than home sleep, worst for team drivers in moving trucks. It did not measure air quality or CO (Confirmed).
Bottom line: a study is warranted. No published study located has measured CO inside an occupied sleeper berth over a full night with source attribution among the truck’s own engine, the bunk heater, the APU, and the neighboring truck. The near-misses are real and they are documented above. None of them is that study. None found as of November 4, 2026.
Sources: 5, 8, 9, 12, 27, 28, 30, 32, 33, 66. Labels: Searched, none located (overnight occupied CO measurement; driver follow-up). Confirmed (Table 7 values; Lee 2009 and Mabvuta 2015 as described; Cheng/Tan winter cab CO during idling at low single-digit ppm). Scoped (single truck, single site; Rudell chamber filter test).
Part eleven: What the other modes require
Aviation, rail, and marine all move people and freight, and all three have dealt with carbon monoxide. Only one of them requires a detector where its workers sleep.
Rail requires it. 49 CFR 228.331(c) says each sleeping room in a railroad camp car must have a working smoke alarm and a working carbon monoxide alarm, or a working combined unit. A camp car is sleeping quarters a railroad provides for train crews, signal workers, dispatchers, and maintenance-of-way workers. The rule took effect December 30, 2011 (76 FR 67073). When a railroad gets notice of a dead alarm, it has 24 hours to fix it or stop using the car as sleeping quarters (49 CFR 228.333). Label: Confirmed (rule text read on eCFR).
That is the direct analog of a truck sleeper berth. Railroad workers sleep in company-provided quarters, and the federal rule puts a CO alarm in the room. Truck drivers sleep in company-provided berths, and no federal rule puts one there.
The rail rule has a hole worth noting. It says the alarm must be “functional” but sets no test interval, no calibration schedule, and no alarm recordkeeping. A weekly test rule for trucks, like the one this brief proposes, would be stricter than what rail requires today. Labels: Confirmed (rule text); the comparison is the author’s.
Locomotive cabs get no detector. 49 CFR 229.43 only requires that combustion products be vented outside the cab. The 2024 update to 49 CFR Part 227 requires emergency escape breathing apparatus for hazmat-train crews, which is respiratory protection for a release. No FRA advisory or rulemaking on cab CO detectors was located. Labels: Confirmed (rule text); Searched, none located (FRA advisory or rulemaking).
Aviation has no federal detector mandate. 14 CFR 23.831(a) and 25.831(b)(1) cap carbon monoxide at 1 part in 20,000 parts of air (50 ppm) as a design and ventilation standard. 14 CFR 27.859 requires heater designs that keep CO out of rotorcraft cabins. Those govern how the aircraft is built.
The NTSB asked twice. In 2004 (A-04-28) it asked the FAA to require CO detectors in single-engine piston airplanes. The FAA declined, and the NTSB closed the recommendation as unacceptable action in 2011. In January 2022 (A-22-001, from report AIR-22-01) it asked again for enclosed-cabin piston aircraft. No mandate followed. The FAA’s standing guidance is voluntary: SAIB CE-10-19 R1 (2010) recommends installing a commercially available detector, and TSO-C48A sets the performance standard for units installed voluntarily. The FAA’s 2009 technology survey (DOT/FAA/AR-09/49) judged electrochemical sensors the best fit for aircraft. Labels: Confirmed (NTSB recommendations and report, FAA documents).
The accident count behind those recommendations: 31 CO accidents from 1982 to 2020, 23 of them fatal, 42 people killed and 4 seriously injured. Only one of those airplanes carried any detector, a passive color-change card, expired, with no audible warning. Label: Confirmed (NTSB/AIR-22-01).
What pilots actually buy comes in two kinds. Portable electrochemical units with digital readouts, like the Sensorcon AV8 (alarms at 35 and 200 ppm, over two years of battery). Panel-mounted TSO-C48A units wired to aircraft power, like the Guardian Aero 452 (85-decibel alarm above 50 ppm) and the Garmin GCO 14 (sensor life up to 10 years). No federal maintenance rule exists because the equipment is voluntary. Makers specify sensor lives of 5 to 10 years. Labels: Confirmed (manufacturer listings).
Marine has no federal detector mandate either. On inspected small passenger vessels the Coast Guard requires smoke detection under 46 CFR 181.405 and 181.450 (UL 217). CO is not covered. The 2021 small-passenger-vessel fire interim rule and the Coast Guard’s March 2024 clarification both address fire and smoke detection. For recreational boats there is no federal CO detector rule at all.
The industry standard is voluntary. ABYC A-24 recommends CO detection systems on boats with enclosed accommodations plus a gasoline generator or inboard gasoline engine, for boats built after July 31, 2016. Internationally, SOLAS Chapter XI-1 Regulation 7 (in force July 1, 2016) requires ships on international voyages to carry portable atmosphere-testing instruments that read oxygen, flammables, hydrogen sulfide, and carbon monoxide. Those are occupational instruments for enclosed-space entry. Labels: Confirmed (ABYC standard preview, USCG documents).
The deaths behind the recommendations are documented. At Lake Powell in August 2000, two boys swimming near a houseboat stern died from generator CO. The CDC investigation tied 9 fatal and about 100 nonfatal boat CO poisonings to the lake since 1990. A NIOSH case listing identified 93 fatal and 377 nonfatal boat CO poisonings through March 2003, and NIOSH judged that an undercount. Labels: Confirmed (CDC MMWR); NIOSH aggregate as reported.
Marine detectors are built for the environment: fixed 12 or 24 volt units with battery backup, electrochemical sensors, 85-decibel alarms, interconnectable, some able to shut down a generator. The Fireboy-Xintex CMD6-MD-R alarms on a time-weighted 10 percent carboxyhemoglobin basis with about a 7-year sensor life. The MTI Safe-T-Alert 62 series is UL 2034 listed with a 5-year end-of-life signal. Both build to UL 2034’s time-weighted bands: 70 ppm within 60 to 240 minutes, 150 ppm within 10 to 50, 400 ppm within 4 to 15, no alarm below 30 ppm. No federal maintenance rule. Makers specify 5 to 7 year replacement and a test-button check before each use. Labels: Confirmed (manufacturer listings).
The comparison, mode by mode:
| Mode | Federal CO-detector requirement | Citation | Typical detector and maintenance |
| Aviation | None | No 14 CFR mandate; TSO-C48A is an approval standard; SAIB CE-10-19 R1 is voluntary | Portable electrochemical (35/200 ppm) or installed TSO-C48A wired to aircraft power; no federal maintenance rule, makers specify 5 to 10 year sensor life |
| Rail | Yes for camp-car sleeping rooms; none for locomotive cabs | 49 CFR 228.331(c), effective Dec. 30, 2011 | Residential-type electrochemical CO/smoke alarms (UL 2034 bands); must be “functional,” no test or calibration interval in the rule |
| Marine | None federal | No 33/46 CFR mandate; 46 CFR 181 covers smoke only; ABYC A-24 voluntary | Fixed 12/24-volt marine CO alarms (UL 2034, 85 dB, interconnect); no federal maintenance rule, makers specify 5 to 7 year replacement |
Bottom line: the FRA already decided that workers who sleep in company-provided quarters get a carbon monoxide alarm. The truck sleeper berth is that same arrangement, and it has no such rule. Aviation and marine show what the voluntary path produces: recommendations, standards, and deaths that did not stop.
Sources: 4, 38 through 58. Labels as shown in the text.
A companion brief, Series 11 Brief 12, covers what the record says about low-level CO and driver judgment.
Primary sources
PMID is the PubMed identifier. DOI is the digital object identifier.
1. ATSDR. Toxicological Profile for Carbon Monoxide (TP-201), Chapter 3: Coburn-Forster-Kane table (M = 218, range 191 to 257), half-life discussion, and muscle uptake model. Peterson and Stewart (1970) and Bruce and Bruce (2006) are cited as reported there. https://www.ncbi.nlm.nih.gov/books/NBK153687 and https://www.atsdr.cdc.gov/ToxProfiles/tp201-c3.pdf
2. Peterson and Stewart (1970); Bruce and Bruce (2006): half-life values as reported in source 1. Peterson and Stewart (1970), Arch Environ Health 21:165-171: https://firedoc.nist.gov/article/G3cyXYQBWEcjUZEYH03h Bruce and Bruce (2006), as reported in source 1: https://www.ncbi.nlm.nih.gov/books/NBK153687
3. 49 CFR 392.66; 393.76; 393.77; 393.83; 395.1(g); 395.3(a)(1); Part 396, Appendix A. Electronic Code of Federal Regulations (Cornell Legal Information Institute copy). https://www.ecfr.gov/current/title-49/subtitle-B/chapter-III/subchapter-B
4. NTSB. Require Carbon Monoxide Detectors in Certain General Aviation Aircraft, NTSB/AIR-22-01 (report dated December 20, 2021). ntsb.gov.https://www.ntsb.gov/investigations/AccidentReports/Reports/AIR2201.pdf
5. Fu JS, Calcagno JA III, Davis WT, Boulet JAM, Wasserman JF. Improving Heavy-Duty Diesel Truck Ergonomics to Reduce Fatigue and Improve Driver Health and Performance. FMCSA-RRR-10-010 (final report), December 2010, University of Tennessee, govinfo.gov. Tech Brief FMCSA-RRR-10-010-TB. https://www.govinfo.gov/content/pkg/GOVPUB-TD2_300-PURL-gpo9263/pdf/GOVPUB-TD2_300-PURL-gpo9263.pdf The Executive Summary and sections 3, 4.5.2, 4.5.3, 5.3.1 and 5.3.2 were read on November 4, 2026, from the copies at https://rosap.ntl.bts.gov/view/dot/48 (final report) and https://rosap.ntl.bts.gov/view/dot/49 (Tech Brief). The parked-against-on-road ratios of 1.5, 7.1 and 3.0 are from the Executive Summary and section 5.3.2; the Tech Brief gives 1.3, 4.8 and 4.5. Doraiswamy et al. values are as reported on page 8 of the final report. Also published as Fu JS, Calcagno JA III, Davis WT, Alvarez A. Transportation Research Record 2194:29-36, 2010. The journal version was not read beyond its abstract. Its full text is behind a paywall and is not publicly available.
6. Manke A, Hicks P, Hankey JM. Pilot In-Vehicle Carbon Monoxide Detector Study. National Surface Transportation Safety Center for Excellence, Virginia Tech Transportation Institute. VTechWorks, posted March 28, 2025. Data collected July to December 2023. https://vtechworks.lib.vt.edu/handle/10919/125115
7. Dirks KN et al. 2018. Atmosphere 9(9):338. In-vehicle CO; 171 ppm peak (body section 3.3). https://doi.org/10.3390/atmos9090338
8. EPA. Air Quality Criteria for Carbon Monoxide, EPA 600/P-99/001F, June 2000, section 1.4.9 and Chapter 6. EPA. Integrated Science Assessment for Carbon Monoxide, EPA/600/R-09/019F, January 2010. EPA CO standards retention, August 31, 2011. Clean Air Scientific Advisory Committee review of the Integrated Science Assessment second external review draft (nepis.epa.gov); The final 2010 assessment was read for this brief: https://www.epa.gov/system/files/documents/2026-06/isa-annexes_co_final.PDF. EPA assessment history (2000 and 2010 documents): https://www.epa.gov/isa/integrated-science-assessment-isa-carbon-monoxide Final 2010 assessment record: https://assessments.epa.gov/risk/document/&deid=218686
9. WHO. Global air quality guidelines, 2021 (CO: 4, 10, 35, 100 mg/mÂł at 24 h, 8 h, 1 h, 15 min). WHO Guidelines for Indoor Air Quality: Selected Pollutants, 2010 (CO: 7 mg/mÂł over 24 h). NIOSH. Pocket Guide to Chemical Hazards, carbon monoxide (REL: 35 ppm 8-hour average, 200 ppm ceiling; cdc.gov/niosh/npg/npgd0105). https://www.cdc.gov/niosh/npg/npgd0105.html OSHA permissible exposure limit, 50 ppm 8-hour (29 CFR 1910.1000). https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1000 WHO 2021 guidelines: https://www.who.int/europe/publications/i/item/9789240034228 WHO 2010 indoor guidelines: https://www.who.int/publications/i/item/9789289002134
10. NIOSH Science Bulletin, Centers for Disease Control and Prevention, 2010: 51% of long-haul drivers smoke against 19% of working adults. https://www.cdc.gov/niosh/bulletin/2015/truck-driver-health.html and https://pmc.ncbi.nlm.nih.gov/articles/PMC4511102
11. Allred EN et al. 1989. N Engl J Med 321:1426. PMID 2682242. Kleinman MT et al. 1989. Arch Environ Health 44:361. PMID 2692521. https://pubmed.ncbi.nlm.nih.gov/2682242/ and https://pubmed.ncbi.nlm.nih.gov/2692521/
12. Stern et al. 1981. PMID 6163400 (New Jersey motor vehicle examiners). https://pubmed.ncbi.nlm.nih.gov/6163400/ Stern FB, Halperin WE, Hornung RW, Ringenburg VL, McCammon CS. 1988. Heart disease mortality among bridge and tunnel officers exposed to carbon monoxide. Am J Epidemiol 128(6):1276-88. PMID 2461656. DOI 10.1093/oxfordjournals.aje.a115081. https://stacks.cdc.gov/view/cdc/185694/cdc_185694_DS1.pdf
13. Bol O, Koyuncu S, GĂĽnay N. 2018. Prevalence of hidden carbon monoxide poisoning in auto service workers; a prospective cohort study. J Occup Med Toxicol 13:35. DOI 10.1186/s12995-018-0214-9. https://doi.org/10.1186/s12995-018-0214-9
14. Choi IS. 1983. PMID 6860181. https://pubmed.ncbi.nlm.nih.gov/6860181/ Weaver LK et al. 2002. N Engl J Med 347:1057. PMID 12362006. Weaver LK et al. 2000. Chest 117(3):801 (half-life on 100% oxygen, 74 minutes, standard deviation 25). Weaver 2002: https://www.nejm.org/doi/full/10.1056/NEJMoa013121 Weaver 2000: https://pubmed.ncbi.nlm.nih.gov/10713010
15. Griffin SM, Ward MK, Terrell AR, Stewart D. 2008. Diesel fumes do kill. J Forensic Sci 53(5):1206-11. PMID 18643868. DOI 10.1111/j.1556-4029.2008.00804.x. Abstract read only. The full text is behind a paywall and is not publicly available. https://pubmed.ncbi.nlm.nih.gov/18643868/
16. Ho et al. 2026. J Clin Med 15(6):2338. DOI 10.3390/jcm15062338. https://www.mdpi.com/2077-0383/15/6/2338
17. Moss et al. 2025. PLOS ONE. Scoping review, 80 papers. https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0300989
18. Delvau et al. 2024. Toxicol Rep. PMID 38433766 (swine model, 940 ppm). https://pubmed.ncbi.nlm.nih.gov/38433766/
19. Washington State FACE report 71-254-2024. OSHA IMIS inspections 143281.015, 14529671, 200626349, 14388052. WA FACE report: https://www.lni.wa.gov/safety-health/safety-research/files/2024/71_254_2024_TruckDriverCOPoisoning.pdf OSHA IMIS inspection pages: https://www.osha.gov/ords/imis/establishment.inspection_detail?id=143281.015 https://www.osha.gov/ords/imis/establishment.inspection_detail?id=14529671 https://www.osha.gov/ords/imis/establishment.inspection_detail?id=200626349 https://www.osha.gov/ords/imis/establishment.inspection_detail?id=14388052
20. Occupational Safety and Health Act of 1970, section 4(b)(1), 29 U.S. Code 653(b)(1). Chao v. Mallard Bay Drilling, Inc., 534 U.S. 235 (2002). https://supreme.justia.com/cases/federal/us/534/235/ Statute: https://www.law.cornell.edu/uscode/text/29/653,OSHA, Review of Policy on Section 4(b)(1) of the Act (July 10, 1989), https://www.osha.gov/laws-regs/standardinterpretations/1989-07-10, and OSHA Trucking Industry Standards page, https://www.osha.gov/trucking-industry/standards
21. State idling statutes and rules, fifty-state read. American Transportation Research Institute, Idling Regulations Compendium (June 2025, updated August 2026): https://truckingresearch.org/wp-content/uploads/2025/06/2025-ATRI-Idling-Compendium.pdf. Rule texts read: California, 13 CCR 2485, https://www.law.cornell.edu/regulations/california/13-CCR-2485. Colorado, C.R.S. 42-14-105 as amended by HB24-1341, https://law.justia.com/codes/colorado/title-42/idling-standard/article-14/section-42-14-105/ and https://content.leg.colorado.gov/sites/default/files/2024a_1341_signed.pdf. Connecticut, RCSA 22a-174-18(b)(3), https://www.epa.gov/system/files/documents/2022-09/22a-174-18.pdf. Delaware, 7 DE Admin. Code 1145, https://regulations.delaware.gov/AdminCode/title7/1145. District of Columbia, 20 DCMR 900.1 (agency text of the rule; exceptions as quoted in the District’s 2019 complaint against Greyhound), https://doee.dc.gov/sites/default/files/dc/sites/ddoe/publication/attachments/20-900%20%281%29.pdf and https://oag.dc.gov/sites/default/files/2019-12/DC-v-Greyhound-Complaint.pdf. Georgia (Atlanta ordinance only), https://epa.gov/sites/default/files/documents/CompilationofStateIdlingRegulations.pdf. Hawaii, HAR 11-60.1-34(c), https://www.law.cornell.edu/regulations/hawaii/Haw-Code-R-SS-11-60-1-34. Idaho, House Bill 533 (2024), https://legislature.idaho.gov/wp-content/uploads/sessioninfo/2024/legislation/H0533.pdf. Maine, 38 MRSA 585-L, https://legislature.maine.gov/statutes/38/title38sec585-L.html. Maryland, Transportation Article 22-402(c)(3), https://law.justia.com/codes/maryland/transportation/title-22/subtitle-4/section-22-402/. Massachusetts, 310 CMR 7.11(1)(b), https://www.law.cornell.edu/regulations/massachusetts/310-CMR-7-11. Missouri, 10 CSR 10-5.385, https://www.epa.gov/sites/default/files/2017-09/documents/10-5385_0.pdf. Nevada, NAC 445B.576(4), https://www.law.cornell.edu/regulations/nevada/NAC-445B-576. New Hampshire, Env-A 1102.02 and 1102.03, https://www.law.cornell.edu/regulations/new-hampshire/N-H-Admin-Code-SS-Env-A-1102.02 and https://www.law.cornell.edu/regulations/new-hampshire/N-H-Admin-Code-SS-Env-A-1102.03. New Jersey, N.J.A.C. 7:27-14.3, https://www.epa.gov/sites/production/files/2018-07/documents/7.27-14.3_oct_2016_eff_date_0.pdf. New York, 6 NYCRR 217-3, https://www.law.cornell.edu/regulations/new-york/6-NYCRR-217-3.3. North Carolina, repeal under S.L. 2015-286, https://library.ncleg.gov/Legislation/SummariesPublication/Summary/2015/10/H765-SMTA-45(sl)/. Oregon, ORS 825.605 to 825.610 (2011 Or. Laws ch. 349), https://www.oregonlegislature.gov/bills_laws/lawsstatutes/2011orLaw0349.html. Pennsylvania, Act 124 of 2008, https://www.legis.state.pa.us/WU01/LI/LI/US/HTM/2008/0/0124..HTM. Rhode Island, RIGL 31-16.1-3, https://law.justia.com/codes/rhode-island/title-31/chapter-31-16-1/section-31-16-1-3/. South Carolina, Code 56-35-20, https://law.justia.com/codes/south-carolina/title-56/chapter-35/section-56-35-20/. Texas, 30 TAC 114.512, https://www.law.cornell.edu/regulations/texas/30-Tex-Admin-Code-SS-114-512. Vermont, 23 V.S.A. 1110, https://legislature.vermont.gov/statutes/section/23/013/01110. Virginia, 9VAC5-40-5670(C), https://law.lis.virginia.gov/admincode/title9/agency5/chapter40/section5670/. West Virginia, 17C-13A-2, https://code.wvlegislature.gov/17C-13A-2.
22. NFPA 1192, Standard on Recreational Vehicles, 2026 edition, Sections 1.1 and 1.3.1 (page 1192-5), 3.3.53 (page 1192-9) and 6.1.2 (page 1192-21). https://link.nfpa.org/free-access/publications/1192/2026
23. ILO Encyclopaedia of Occupational Health and Safety, 4th edition, chapter 104, Guide to Chemicals: Carbon Monoxide (iloencyclopaedia.org, item 1063). Read in full. https://iloencyclopaedia.org/part-xviii-10978/guide-to-chemicals/item/1063-carbon-monoxide
24. Lacerda ABM, Leroux T, Gagné JP. 2005. The combined effect of noise and carbon monoxide on hearing thresholds of exposed workers (9,396 audiograms, Quebec National Public Health Institute, 1983 to 1996). Abstract. Leroux T, Lacerda A, Gagné JP. 2008. Auditory effects of chronic exposure to carbon monoxide and noise among workers. 9th Congress of the International Commission on the Biological Effects of Noise. Full text read. https://www.icben.org/2008/PDFs/Leroux_et_al.pdf
25. Assadi SN. 2019. The health effects of carbon monoxide in chronic exposure to low concentrations. Int J Med Sci Public Health 8(6):465-469. DOI 10.5455/ijmsph.2019.0305022042019. Full text read. https://dx.doi.org/10.5455/ijmsph.2019.0305022042019
26. Figures 1 and 2 are calculated from the values in sources 1, 2, 3, 6, 7 and 9.
27. Lee D-W, Zietsman J, Farzaneh M, Li W-W, Olvera HA, Storey JME, Kranendonk L. In-Cab Air Quality of Trucks Air Conditioned and Kept in Electrified Truck Stop. Transportation Research Record 2123:17-25, 2009. DOI 10.3141/2123-03. https://doi.org/10.3141/2123-03 Table 3 prints no units; CO values read as parts per billion.
28. Mabvuta GF. Assessing Potential Diesel Exhaust Exposure in Truckers Resting at Truck Stops. Master of Science thesis, University of Alabama at Birmingham, 2015. UAB Digital Commons, All ETDs from UAB, item 2358. https://digitalcommons.library.uab.edu/etd-collection/2358 The abstract and text give EC values that differ from Table 4; Table 4 values are used. Appendix N lists different values than Table 4 (PM2.5 inside and outside reversed, and EC at 4.72 and 1.95). The thesis states no CO measurement. A results sentence lists “CO” among analytes, which reads as a typo for OC.
29. EPA. Reconsideration of the National Ambient Air Quality Standards for Particulate Matter. Federal Register document 2024-02637 (March 6, 2024). https://www.federalregister.gov/documents/2024/03/06/2024-02637/reconsideration-of-the-national-ambient-air-quality-standards-for-particulate-matter EPA. Initial Air Quality Designations for the 2024 Revised Primary Annual Fine Particle (PM2.5) National Ambient Air Quality Standards. Federal Register document 2026-20468 (October 6, 2026). https://www.federalregister.gov/documents/2026/10/06/2026-20468/initial-air-quality-designations-for-the-2024-revised-primary-annual-fine-particle-pm25-national
30. Yeh M, Pollard JK. Emissions Impacts on Driver Safety. FMCSA-RRA-07-012, DOT-VNTSC-FMCSA-07-02. John A. Volpe National Transportation Systems Center, prepared for FMCSA, July 2007. https://ai.fmcsa.dot.gov/carrierresearchresults/PDFs/Driver/Emissions%20Impact%20on%20Driver%20Safety%20Final%20Report.pdf The executive summary, Section 3.2.2 and Section 4 were read. Wright et al. (1973), McFarland (1973) and O’Donnell et al. (1971) are cited as reported there.
31. Davis ME, et al. Driver Exposure to Combustion Particles in the U.S. Trucking Industry. J Occup Environ Hyg 4(11):848-854, 2007. DOI 10.1080/15459620701643347. PMID 17885912. https://pmc.ncbi.nlm.nih.gov/articles/PMC2292342/ The abstract and the truck age discussion were read. The age finding rests on elemental carbon, not CO, and the age graph shows pickup and delivery drivers.
32. Cheng X. Air Quality in Commercial Truck Cabins and Its Effect of Health and Alertness. Doctoral dissertation, University of Calgary, Department of Mechanical and Manufacturing Engineering, 2006.
33. Tan Z, Tay R. Sources Contributing to PM2.5 in a Commercial Truck Cabin in Winter. Transportation Research Part D: Transport and Environment 13:54-58, 2008.
34. FMCSA. Study of Alternatives to Reduce Driver Exposure to Diesel Exhaust. Project page: goal, background (air pollution measured inside cabs and berths at truck stops, exceeding EPA standards, worse when idling), summary (pollutant of concern: diesel particulate matter), milestones 2015-2016, funding FY2015 $481,078, contractors UMTRI/TTI/Georgia Tech, status complete. https://www.fmcsa.dot.gov/research-and-analysis/research/study-alternatives-reduce-driver-exposure-diesel-exhaust
35. UNECE Informal Working Group on VIAQ. Terms of reference and rules of procedure, third stage. Informal document GRPE-81-09, 81st GRPE, 9-11 June 2020. Confirms M.R.3 adopted at 173rd WP.29 (Nov 2017), published 1 Nov 2018 as ECE/TRANS/WP.29/1143; second stage covers exhaust gas entry from the tailpipe with harmonized test procedures, test substances CO, NO, NO2. https://wiki.unece.org/download/attachments/25266269/GRPE-81-09e.pdf?api=v2
36. UNECE IWG on VIAQ. Mutual Resolution No. 3 general provisions (first stage). Informal document GRPE-75-03. This Mutual Resolution does not hold regulatory status within Contracting Parties. The setting of interior emission limit values, therefore, is not part of this recommendation for the time being. https://wiki.unece.org/download/attachments/50003982/GRPE-75-03.pdf?version=1&modificationDate=1495727015585&api=v2
37. Euro-Asian Council for Standardization, Metrology and Certification (NAMI, Russian Federation). Interior air of road vehicles: pollution content in the interior of driver cab and passenger compartment; technical requirements and test methods. Draft standard submitted to the VIAQ IWG as VIAQ-01-10. Scope: vehicles of M and N categories (N = goods vehicles). Contamination mechanism stated as exhaust gases penetrating through air-conditioning and ventilation systems and cracks. CO determination by gas chromatography with FID after conversion to methane (ISO 8186:1989), optical acoustic infrared spectroscopy, or electrochemical detection. Used in Russian Federation vehicle certification. https://wiki.unece.org/download/attachments/25269016/VIAQ-01-10.pdf?api=v2 See also VIAQ-08-07, Introduction to Russian standard GOST 33554-15: Pollutant content in the interior of driver cab and passenger compartment, submitted by NAMI and Russia, posted April 18, 2017 (slide date April 25, 2017). The presentation itself was read on November 4, 2026; see source 70. https://globalautoregs.com/documents/14127
38. Federal Railroad Administration. 49 CFR Part 228, Subpart E, §228.331 (camp car CO alarms); §228.333 (24-hour remedial action); §228.305 (compliance date December 30, 2011). eCFR. https://www.ecfr.gov/current/title-49/subtitle-B/chapter-II/part-228/subpart-E
39. Federal Railroad Administration. Safety and Health Requirements Related to Camp Cars; final rule. 76 FR 67073 (Oct. 31, 2011); effective Dec. 30, 2011. https://www.federalregister.gov/documents/2011/10/31/2011-27818/safety-and-health-requirements-related-to-camp-cars
40. 49 CFR 229.43 (locomotive exhaust venting; design rule, no detector). eCFR. https://www.ecfr.gov/current/title-49/subtitle-B/chapter-II/part-229
41. Federal Railroad Administration. 49 CFR Part 227, occupational safety and health in the locomotive cab; emergency escape breathing apparatus final rule (2024). https://www.transportation.gov/regulations/federal-register-documents/2024-01074
42. National Transportation Safety Board. Press release NR20220120 (Jan. 20, 2022): safety recommendations A-22-001 and A-22-002 on CO detectors in piston aircraft. https://www.ntsb.gov/news/press-releases/Pages/NR20220120.aspx
43. Federal Aviation Administration. SAIB CE-10-19 R1, Engine Exhaust and Carbon Monoxide Detectors (Mar. 17, 2010) (voluntary guidance). https://tc.canada.ca/sites/default/files/migrated/ce_10_19_r1.pdf
44. Federal Aviation Administration. DOT/FAA/AR-09/49, Detection and Prevention of Carbon Monoxide Exposure in General Aviation Aircraft (Oct. 2009). https://csobeech.com/files/FAA-CO-Report.pdf
45. 14 CFR 23.831(a), 25.831(b)(1), 27.859 (CO ventilation and heater design standards; no detector mandate). https://www.law.cornell.edu/cfr/text/14/25.831
46. U.S. Coast Guard. 46 CFR Part 181, fire protection for small passenger vessels (smoke detection, UL 217; no CO requirement). https://www.govinfo.gov/content/pkg/CFR-2017-title46-vol7/pdf/CFR-2017-title46-vol7-part181.pdf
47. U.S. Coast Guard. Clarification on interconnected fire systems onboard covered small passenger vessels (Mar. 2024) (fire/smoke, not CO). https://www.news.uscg.mil/maritime-commons/Article/3709889/announcement-clarification-on-interconnected-fire-systems-onboard-covered-small/
48. American Boat and Yacht Council. Standard A-24, Carbon Monoxide Detection Systems (2015) (voluntary). https://webstore.ansi.org/preview-pages/ABYC/preview_ABYC+A-24-2015.pdf
49. U.S. Coast Guard. 2024 Recreational Boating Statistics. https://www.uscgboating.org/library/accident-statistics/Recreational-Boating-Statistics-2024.pdf
50. Centers for Disease Control and Prevention. MMWR report on Lake Powell boat CO poisonings (2000). https://stacks.cdc.gov/view/cdc/183133/cdc_183133_DS1.pdf
51. NIOSH. “Boat-Related Carbon Monoxide (CO) Poisonings” (93 fatal, 377 nonfatal through Mar. 19, 2003), as summarized. https://www.safetyresearch.net/safety-issues/carbon-monoxide-poisoning-and-boats/
52. International Maritime Organization. SOLAS Chapter XI-1, Regulation 7 (in force July 1, 2016); guidance MSC.1/Circ.1477 (portable atmosphere-testing instruments; occupational, not cabin alarms). http://svg-marad.com/Downloads/Circulars/SOLAS/SOL%20052%20Revised%20Recommendations%20For%20Entering%20Enclosed%20Spaces%20Aboard%20Ships%20-%20Rev.%201.pdf
53. Occupational Safety and Health Administration. 29 CFR 1910.1000 Table Z-1 (CO PEL 50 ppm 8-hour TWA). https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1000TABLEZ1
54. Guardian Avionics. Aero 452 CO detector specifications (TSO-C48A). https://www.aircraftspruce.com/catalog/pspages/ca4521428.php
55. Garmin. GCO 14 carbon monoxide detector (TSO-C48A). https://generalaviationnews.com/2025/04/04/garmin-introduces-its-first-carbon-monoxide-detector-for-aircraft/
56. Sensorcon. AV8 Inspector CO monitor specifications. https://www.aircraftspruce.com/catalog/pspages/sensorcon_av8.php
57. Fireboy-Xintex. CMD6-MD-R marine CO alarm specifications. https://essenbaymarine.com/products/fireboy-xintex-co-alarm-12-24v-dc-white-cmd6-md-r
58. MTI Industries. Safe-T-Alert 62 Series marine CO alarm (UL 2034). https://defender.com/en_us/mti-industries-safe-t-alert-62-series-marine-carbon-monoxide-alarm
59. Demirci S, Dogan KH, Erkol Z, Gunaydin G. Two death cases originating from supplementary heater in the cabins of parked trucks. Journal of Forensic and Legal Medicine 16(2):97-100, 2009. Abstract read only. The full text is behind a paywall and is not publicly available. https://pubmed.ncbi.nlm.nih.gov/19135005/
60. Ziskind R, Carlin T, Axelrod M, Allen RW, Schwartz SH. Toxic Gases in Heavy Duty Diesel Truck Cabs. Report FHWA-RD-77-139, Science Applications, Inc., for the Federal Highway Administration and the Bureau of Motor Carrier Safety, October 1977 (NTIS PB275957; contract DOT-FH-11-9186). Read in full on October 23, 2026, from the free NTIS copy. https://ntrl.ntis.gov/NTRL/dashboard/searchResults/titleDetail/PB275957.xhtml
61. Doraiswamy P, Davis WT, Miller TL, Lam N, Bubbosh P. Air Quality Measurements inside Diesel Truck Cabs during Long-Term Idling. Transportation Research Record 1987:82-91, 2006. Abstract read only. The full text is behind a paywall and is not publicly available. https://journals.sagepub.com/doi/10.1177/0361198106198700109 The underlying 2005 University of Tennessee report to EPA was read in full; see source 64.
62. Couch J, PhD, Branch Chief, Hazard Evaluations and Technical Assistance Branch (HETAB), Centers for Disease Control and Prevention. Personal correspondence (email reply to T. Daum), October 2026. Not a publication.
63. National Institute for Occupational Safety and Health. Health Hazard Evaluation program: request an evaluation. https://www.cdc.gov/niosh/hhe/request/index.html
64. Doraiswamy P, Davis WT, Miller TL, Fu JS, Lam YF. Measuring Air Pollution Inside and Outside of Diesel Truck Cabs. Report prepared for the U.S. Environmental Protection Agency by the University of Tennessee, Knoxville, November 4, 2005, funded by the National Transportation Research Center at Oak Ridge National Laboratory under subcontract from EPA. Read in full from the archived EPA SmartWay copy. In-cab CO maximum from Appendix A-7; findings from Conclusions 1 to 13. https://webarchive.library.unt.edu/web/20130302211902/http://epa.gov/smartway/documents/publications/incabairquality-110405.pdf
65. Davis W, Miller T, Lam Y, Indale G, McCall A. Evaluation/improvement of in-cab air quality at an interstate travel center with truck stop electrification. WIT Transactions on Ecology and the Environment 86:565-574, 2006 (Air Pollution XIV). DOI 10.2495/AIR06056 as printed on the paper; the publisher’s web page lists 10.2495/AIR060561. Open access. Read in full. McCall was with IdleAire Technologies, the electrification vendor tested. Particle mass was computed from laser particle counts assuming a density of 2.5 g/cm³. The text and Table 1 differ on which trucks read higher inside than outside. https://www.witpress.com/elibrary/wit-transactions-on-ecology-and-the-environment/86/16108
66. Rudell B, Wass U, Hörstedt P, Levin J-O, Lindahl R, Rannug U, Sunesson A-L, Östberg Y, Sandström T. Efficiency of automotive cabin air filters to reduce acute health effects of diesel exhaust in human subjects. Occup Environ Med 56(4):222-231, 1999. PMID 10450238. DOI 10.1136/oem.56.4.222. Read in full; CO values from Table 2. https://pmc.ncbi.nlm.nih.gov/articles/PMC1757727
67. Harik G, El-Fadel M, Shihadeh A, Alameddine I, Hatzopoulou M. Is in-cabin exposure to carbon monoxide and fine particulate matter amplified by the vehicle’s self-pollution potential? Quantifying the rate of exhaust intrusion. Transportation Research Part D 54:225-238, 2017. DOI 10.1016/j.trd.2017.05.009. Full text read; averages of 14.61% (CO) and 29.93% (PM2.5) from Table 5. The publisher copy is behind a paywall. https://doi.org/10.1016/j.trd.2017.05.009
68. Behrentz E, Fitz DR, Pankratz DV, Sabin LD, Colome SD, Fruin SA, Winer AM. Measuring self-pollution in school buses using a tracer gas technique. Atmospheric Environment 38(23):3735-3746, 2004. DOI 10.1016/j.atmosenv.2004.04.007. Full text read. The publisher copy is behind a paywall. https://doi.org/10.1016/j.atmosenv.2004.04.007
69. Zhang Y, Li J, Sun H, Liu J, Chen Q. Evaluation of different air distribution systems for sleeping spaces in transport vehicles. Building and Environment 94:665-675, 2015. DOI 10.1016/j.buildenv.2015.11.004. Author manuscript read in full; supply airflow values from Section 4 and Figure 13. https://doi.org/10.1016/j.buildenv.2015.11.004
70. Interstate standard GOST 33554-2015, Motor vehicles. Pollutants content in the interior of driver’s cab and passenger compartment. Technical requirements and test methods. Developed by FSUE NAMI; adopted by the Euro-Asian Council for Standardization, Metrology and Certification, protocol 81-P of October 27, 2015 (Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia, Tajikistan); in force in Russia from April 1, 2017 (Rosstandart order 683-st). Russian text read in full on November 4, 2026; cited sections are Table 1 (limits), the test-method annex (Annex B) and the sampling annex (Annex V, clause V.4.2, sleeping-place point). https://meganorm.ru/mega_doc/norm/gost_gosudarstvennyj-standart/17/gost_33554-2015_mezhgosudarstvennyy_standart_avtomobilnye.html English translation submitted to the VIAQ group as VIAQ-11-06, December 20, 2017 (not read): https://globalautoregs.com/documents/15748 Replaced from July 1, 2025 by GOST 33554-2024 (protocol 176-P of August 30, 2024); its catalog record was read, and its full text was not located free of charge: https://cn.gostinfo.ru/catalog/Details/?id=7582245 Presentation: Bulycheva Z, NAMI, Introduction of Interstate Standard GOST 33554-15, VIAQ-08-07, April 25, 2017, read in full. The presentation gives the scope as M and N vehicles of 50 km/h or more and a sampling height of 1.0 m; the standard text gives M, N, L6 and L7 vehicles of 25 km/h or more and 0.3 to 0.4 m for the sleeping place. The standard text is used. CO conversion: 5.0 mg/mÂł is about 4.4 ppm at 25 degrees Celsius.
71. EPA. Air Quality Criteria for Carbon Monoxide, EPA/600/8-90/045F, December 1991, NTIS PB93-167492, section 10.4.2.11.
72. National Research Council. Emergency and Continuous Exposure Guidance Levels for Selected Submarine Contaminants, Volume 1. National Academies Press, 2007. doi:10.17226/11170. https://www.nationalacademies.org/read/11170/chapter/6
73. Dingus TA, Neale VL, Garness SA, Hanowski RJ, et al. Impact of Sleeper Berth Usage on Driver Fatigue, Final Project Report. Federal Motor Carrier Safety Administration, 2002. https://vtechworks.lib.vt.edu/items/daba99be-ec0b-4307-aa2a-aa9eb2fe2137
Freight Culture Standard. Findings reflect the sources listed as of November 4, 2026.
Author
Todd Daum is a Safety and Compliance professional and the author of From Horses to Diesel Trucks: A History of Modern Trucking (2026). He holds a CDL-A with HAZMAT and Tanker endorsements. He is a retired firefighter (Engineer rank) who served with the Deer Park-Silverton Joint Fire District and the Mason Volunteer Fire Department. His fire service work covered commercial and industrial properties as well as residences. He holds EPA 608 Universal certification in HVAC, OSHA 30-Hour Construction certification, and a Federal Secret Security Clearance. He is an Eagle Scout and a Boy Scouts of America leader and instructor. He writes under the Freight Culture Standard name.